Flow rate adjusted by the amplitude or frequency?

| 0

In general both parameters can be used. As lower amplitudes lead to lower compression in the pump chamber, it is better to do fewer large pump strokes over time. Therefore, try to work at a high amplitude level and decrease the frequency until you reach the required flow rate level. In case the flow pulsation is too high, the amplitude should be lowered and frequency increased.